You are here : Home arrow Showroom arrow Products arrow Commercial Water Purifier arrow the Electromagnetic of Flow Meter
Changzhou kede Water Treatment Equipment Co., Ltd.

the Electromagnetic of Flow Meter

the Electromagnetic of Flow Meter

Keywords: Flow meter
Post Date: 2009-05-13
Description:
Choice assembling location on the pipeline in consumer
In order to survey, You should notice following asked that chance pipeline position.

The transmitter installation both frank pipeline and level or tip pipeline, but asked center of two electrode pole be in level state

The Medium should be full tube following in installation state, avoid to unfilled tube and gas add to electric pole

To each of liquid and solid ,the most of way is perpendicular installation ,Make the Medium from lower to upper, It will be made attrition uniform  in the transmitter, prolong using life-span.

The upper flow direction of transmitter sign responds to the direction being on the move in being in charge of inner medium coincides. That discontented in medium , may adopt the method raising back-end exhalent siphon of flow meter altitude to make medium full at this time manages or uses with other method a sensor to measure the full tube of location.
Price Terms :FOB

More products from this supplier

Didn’t find what you want? Post a buying lead

Send a message
Print Page
E-mail